Typical
build up of Stowell
first floor T profile blocks and
the Stowell T Joist System
Plan
1m
Joist and
block floor dimensions
Section
Lb
Due to increases in floor
mass required to comply with Building Regulations Part
E, Stowell Concrete now offer a T-shaped block, for use
with their 155mm deep floor joists, that will satisfy
the majority of requirements, but will need pre-completion
testing.
Stowell T joist blocks can be used at 374mm or 289mm centres.
Stowell T joist blocks have a nominal density of 1950kg/m3.
Careful consideration of their use should be made at the
design stage as there is less flexibility in their use
e.g. can only use double joists, not triples where joists
interlink.
At 374mm centres the mass of 1m3 of floor = approximately
320kg.
At 289mm centres the mass of 1m3 of floor = approximately
325kg.
Although the system provides a flush soffit it
is not recommended
that a plaster finish is applied directly to them.
TYPE 300
– 21
per pack
approx. pack weight 390kg
TYPE 215
– 28
per pack
approx. pack weight 364kg
Calculation showing mass
of floor at first floor level using block density of
1950kg/m3 and single joists at 374mm centres...
Mjoist.1m
33.21kg
Mblock.1m
86.35kg
Lb
374mm
MF
= mass per unit area
of floor (kg/m2)
Calculation
MF =
(Mjoist.1m + Mblock.1m)/Lb
(33.21
+ 86.35)/0.374 = 319.68kg/m2
Calculation
showing mass of floor at first floor level using block
density of 1950kg/m3 and
single joists at 289mm centres...
Mjoist.1m
33.21kg
Mblock.1m
60.45kg
Lb
289mm
MF
=
mass per unit area of floor (kg/m2)
Calculation
MF =
(Mjoist.1m + Mblock.1m)/Lb
(33.21
+ 60.45)/0.289 = 324.00kg/m2
All products are available
ex works.
Prices on application.
Telephone our sales office for further information and
quotations.
DOWNLOAD
PDF DATA SHEET
FOR THIS PRODUCT
Download
the free adobe PDF viewer by clicking on the icon.