HOME    |    WORKS    |    PRODUCT CATALOGUES    |    CONTACT US
  our range

CONCRETE BLOCKS

 

Dense concrete blocks

 

Hollow and cellular

 

Fibotherm insulating blocks

 

Stowlite lightweight blocks

 

Midi blocks

 

MACRO blocks

 

Generation 2 MACRO blocks

 

T-joist first floor profile blocks

 

Soap bar blocks, coursing and slip bricks

 

Design your own block

 

Padstones

 

T-Joist first floor recessed profile blocks

 

Foundation (trench) blocks

PAVING SLABS

 

Commercial slabs

 

Patio paving and wet cast edgings

 

Tactile and patterned paving

 

Vintage/traditional and decorative

 

Permeable paving

KERBS, EDGINGS & CHANNELS

FLOORING

 

T-joist flooring

 

Hollowcore flooring

 

Flooring blocks

 

Accessories

 

On-site instructions for pre-cast joists

 

On-site instructions for pre-cast hollowcore flooring planks

FLOORING SOLUTIONS

 

For separating floors to help satisfy Robust details part E

 

E-FC-1, 4 and 5

 

E-FC-8, 9 and 11

 

E-FC-1(RSC) and 9(RSC)

 

E-FC-6 and 7

For domestic floors

 

D1, D2 and D5

 

D3 and D4

 

For ground floors to help satisfy Part L

 

L1, L2, L3 and L4

PRE-CAST CONCRETE LINTELS

EDGING, COPING, BOLLARDS AND PILLAR CAPS

 

Edging, bollards & pillar caps

 

Wall coping

FENCING

 

Fencing products

 

Semi-dry economy fencing

 

Portable post bases

 

Concrete barriers

 L1, L2, L3 and L4

Stowell solutions for ground floors to help satisfy
Part L

L1

• precast concrete plank
•screed laid on generic insulation

 
65-75mm screed
 
Vertical edge strip
 
Insulation
 
Stowell 155mm deep C type joists
 
DPC
Stowell
100mm blocks
 

L2

• joist* & TETRiS block floor with reinforced concrete topping

Gap
strip
75mm reinforced concrete topping
 
TETRiS vertical edge strip
 
TETRiS insulation block
 
Stowell 155mm deep C type T joists
 
DPC
Infill block
 

L3

• hollowcore plank floor
•screed laid on generic insulation

 
 
65-75mm screed
Vertical edge strip
 
Insulation
 
Stowell hollowcore HC260 or HC300 concrete planks
 
DPC
 

L4

• joist* and Beamshield Plus with structural concrete topping

 
 
 
Structural concrete
Vertical edge strip min. 30mm wide
 
Cut Beamshield Plus infill block
 
Stowell 155mm deep C Type T joists
 
DPC
Beamshield
Plus infil block
 
*commonly known as beam

Zero cold bridging solutions

L1. Stowell joist*, block and insulation

 
vertical edge strip
 
Screed 65mm/75mm
 
Insulation generally 75mm (λ 0.023 or less)
 
Stowell 100mm block
 
Stowell 155mm deep
C-Type T joists

L2. Stowell joist* and TETRiS

Insulation level
fixed at 75mm
above beams
Tetris vertical edge strip 75mm
TETRiS gap strip 75mm thick to suit
 
75mm reinforced concrete
 
TETRiS insulation block
 
Infill block 60mm wide gap strip
Stowell 155mm deep C-Type T joists

L3. Stowell hollowcore and insulation

 
vertical edge strip
 
Screed 65mm/75mm
 
Insulation generally 75mm (λ 0.023 or less)†
 
Stowell hollowcore HC260 or HC300 concrete plank

L4. Stowell joist* and Beamshield Plus

Vertical
edge strip
540mm/270mm
width block
 
Beamshield Plus end unit cut from full or half unit**
Reinforced concrete
         Min 150mm void
Beamshield Plus infil block
 
Stowell 155mm deep C Type T joists
Beamshield Plus starter unit**
* commonly known as beam
**so that the structural concrete can extend max 300mm span beyond T beam
 
Building Regulations Part L
To underline the UK Government’s commitment to reduce greenhouse gases, it has amended Approved document L (England and Wales): Conservation of Fuel and Power, and implemented the European Union’s Energy Performance of Building Directive (EPBD). The changes have a significant effect on current design and construction practices. Since 1st April 2007, all new and qualifying buildings have to comply with the new legislation. For Scotland, the requirements are detailed in Section 6 – Energy, which came into force on 1st May 2005.

Objectives of Part L
ADL 2006 sets out to make buildings more energy efficient, with an aim to reduce carbon production by one million tons per year. To satisfy EPBD requirements, new buildings’ energy performance standards must be 20-28% lower than the ADL 2002 notional building Target CO2 Emission Rate (TER), based on the whole building.

New document structure
ADL 2006 is significantly different from previous Approved Documents, in both layout and content. The new document is split into four parts, reflecting the specialisation in the construction market...

• L1A: New dwellings
• L1B: Work on existing dwellings
• L2A: New building – other than dwellings
• L2B: Work on existing buildings – other
than dwellings.

New dwellings
L1A: The maximum permitted U-value for floors is 0.25 W/m2K but the whole house needs to be 20% lower than notional building figures, which for floors is 0.25 W/m2K, therefore the U-value of 0.2 W/m2K will comply.

Work on existing dwellings
L1B: The maximum permitted U-value is 0.22 W/m2K for floors.
All products are available ex works.
Prices on application.
Telephone our sales office for further information and quotations.
DOWNLOAD PDF DATA SHEET
FOR THIS PRODUCT
 



Please consult our design team on 01934 834000.

Stowell 155 T joists, Stowell blocks, insulation and screed enable builders to achieve required U-values for ground floor construction fully complying with Part L of the Building Regulations (England and Wales) 2005.

Please send your plans to our flooring department so we can calculate joist* and block layouts.
Stowell 155 T joists with TETRiS insulation blocks and reinforced concrete enable builders to achieve required U-values for ground floor construction fully complying with Part L of the Building Regulations (England and Wales) 2005.

Please send your plans to our flooring department so we can calculate joist* and block layouts and TETRiS layout.
Stowell hollowcore concrete planks, insulation and screed enable builders to achieve required U-values for ground floor construction fully complying with Part L of the Building Regulations (England and Wales) 2005.

Please send your plans to our flooring department so we can calculate hollowcore layouts.
Stowell 155 T joists, Beamshield Plus and reinforced concrete enable builders to achieve required U-values for ground floor construction fully complying with Part L of the Building Regulations (England and Wales) 2005.