3.6N/mm2 (OVEN-DRY DENSITY approx 850 kg/m3 )
Size
mm
nominal
approx
weight kg
no. per
tonne
multiples
of
no. per
pack
440x215x75
6.7
150
56
112
440x215x100
9.0
110
44
88
440x215x140
12.5
80
32
64
440x215x190
17.2
58
20
40
Course
adjusters
65x215x100
1.35
740
128
512
65x215x140
1.9
530
96
384
U-Value 0.21
19mm sand/cement render (λ 1.00)
0.019
100mm Fibotherm 3.6N/mm2 (λ 0.29)
0.345
50mm low emissivity cavity
0.640
50mm foil-faced partial fill PIR/PU board (λ 0.022)
2.273
100mm Fibotherm 3.6N/mm2 (λ 0.27)
0.370
25mm phenolic insulation (λ 0.022)
1.136
13mm plasterboard
(λ 0.21)
0.062
Sum of resistances
5.185 m2 K/W
Uncorrected U-value
0.193 W/m2 K
Wall tie correction - Staifix HRT4-225
0.001
U-Value 0.25
19mm sand/cement render (λ 1.00)
0.019
100mm Fibotherm 3.6N/mm2 (λ 0.29)
0.345
100mm high performance mineral wool (λ 0.032)
3.125
100mm Fibotherm 3.6N/mm2 (λ 0.27)
0.370
13mm dense plaster (λ 0.57)
0.023
Sum of resistances
4.052 m2 K/W
Uncorrected U-value
0.247 W/m2 K
Wall tie correction - Staifix HRT4-225
0.001
U-Value 0.27
19mm sand/cement render (λ 1.00)
0.019
100mm Fibotherm 3.6N/mm2 (λ 0.29)
0.345
50mm low emissivity cavity
0.640
50mm foil-faced partial fill PIR/PU board (λ 0.022)
2.273
100mm Fibotherm 3.6N/mm2 (λ 0.27)
0.370
13mm dense plaster (λ 0.57)
0.023
Sum of resistances
3.840 m2 K/W
Uncorrected U-value
0.260 W/m2 K
Wall tie correction - Staifix HRT4-225
0.001
Stowell Fibotherm
blocks are
ideal for...
INNER OR OUTER LEAF OF CAVITY
WALLS
PARTITION WALLS
Stowell Fibotherm blocks offer the following advantages...
HIGH INSULATION
LOW SHRINKAGE
LOW SITE BREAKAGE
LOW DENSITY
GOOD FIXING
EXCELLENT PLASTER KEY
THERMAL CONDUCTIVITY: λ*
0.27 W/mK* @ 3% m/c (Inside skin)
0.29 W/mK* @ 5% m/c (Outside skin)
THERMAL
RESISTANCE:
Size
mm
m2 K/W
at:
m2 K/W
at:
75
3%m/c
0.278
5%m/c
0.259
100
3%m/c 0.370
5%m/c
0.345
140
3%m/c
0.519
5%m/c
0.483
190
3%m/c
0.704
5%m/c
0.655
(m/c
= moisture content)
SOUND INSULATION:**
39dB(A) 75mm single skin,
100kg/m2
41dB(A) 100mm single skin, 125kg/m2
42dB(A) 140mm single skin, 165kg/m2
44dB(A) 190mm single skin, 210kg/m2
FIRE RESISTENCE:***
75mm (single skin unplastered) –
100mm (single skin unplastered) 2 hrs
140mm (single skin unplastered) 3 hrs
190mm (single skin unplastered) 6 hrs
For walls, U-value calculations of
0.30 W/m2 K or lower must be obtained for new dwellings (L1A) but in practice, to achieve satisfactory SAP rating, walls need to be designed in the region of
0.25 W/m2 K to 0.28 W/m2 K. 0.28 W/m2 K is the requirement for work on existing buildings (L1B).
*
Calculated from oven dry density
**
Calculated using mass law curve - BS8233 (with 2 skins of dense plaster each 17kg/m2 )
***
Calculated using table 14
BS5628-3 2005
DOWNLOAD
PDF DATA SHEET
FOR THIS PRODUCT
| | |
Stowell
Concrete Limited, Arnolds Way, Yatton Bristol BS49 4QN
Tel: 01934 834000 Fax: 01934 835474 Email:
Registered Name: Stowell Concrete Limited. Place of Registration: England. Registered No: 1059577.
Address of Registered Office: Arnolds Way, Yatton, Bristol BS49 4QN
site design: