HOME    |    WORKS    |    PRODUCT CATALOGUES    |    CONTACT US
  our range

CONCRETE BLOCKS

 

Dense concrete blocks

 

Hollow and cellular

 

Fibotherm insulating blocks

 

Stowlite lightweight blocks

 

Midi blocks

 

MACRO blocks

 

Generation 2 MACRO blocks

 

T-joist first floor profile blocks

 

Soap bar blocks, coursing and slip bricks

 

Design your own block

 

Padstones

 

T-Joist first floor recessed profile blocks

 

Foundation (trench) blocks

PAVING SLABS

 

Commercial slabs

 

Patio paving and wet cast edgings

 

Tactile and patterned paving

 

Vintage/traditional and decorative

 

Permeable paving

KERBS, EDGINGS & CHANNELS

FLOORING

 

T-joist flooring

 

Hollowcore flooring

 

Flooring blocks

 

Accessories

 

On-site instructions for pre-cast joists

 

On-site instructions for pre-cast hollowcore flooring planks

FLOORING SOLUTIONS

 

For separating floors to help satisfy Robust details part E

 

E-FC-1, 4 and 5

 

E-FC-8, 9 and 11

 

E-FC-1(RSC) and 9(RSC)

 

E-FC-6 and 7

For domestic floors

 

D1, D2 and D5

 

D3 and D4

 

For ground floors to help satisfy Part L

 

L1, L2, L3 and L4

PRE-CAST CONCRETE LINTELS

EDGING, COPING, BOLLARDS AND PILLAR CAPS

 

Edging, bollards & pillar caps

 

Wall coping

FENCING

 

Fencing products

 

Semi-dry economy fencing

 

Portable post bases

 

Concrete barriers

 Fibotherm lightweight insulating blocks

Using Fibotherm insulation blocks with specific types of insulation achieves the following ‘U’ values expressed in W/m2K**

OPTION 1
FULL FILL

Outside resistance
100mm block+19mm render
100mm Dritherm standard
100mm Stowell Fibotherm
12.5mm drylining on Dabbs
Inside resistance
Sum of resistances
Uncorrected U-value
Correction
U-VALUE
0.040
0.136
2.703
0.400
0.230
0.130
3.639 m2K/W
0.273 W/m2K
0.026
0.300 W/m2K
Full Fill Fibotherm Insulating Block

OPTION 2
PARTIAL FILL

Outside resistance
105mm brick
50mm low emissivity cavity
50mm Kingspan TW50
100mm Stowell Fibotherm
12.5mm drylining on Dabbs
Inside resistance
Sum of resistances
Uncorrected U-value
Correction
U-VALUE
0.040
0.136
0.644
2.174
0.400
0.230
0.130
3.754 m2K/W
0.266 W/m2K
0.026
0.292 W/m2K
Partial Fill Fibotherm Insulating Block

OPTION 3
PARTIAL FILL

Outside resistance
100mm block+19mm render
50mm low emissivity cavity
50mm Kingspan Kooltherm K8
100mm Stowell Fibotherm
12.5mm drylining on Dabbs
Inside resistance
Sum of resistances
Uncorrected U-value
Correction
U-VALUE
0.040
0.136
0.644
2.380
0.400
0.230
0.130
3.960 m2K/W
0.252 W/m2K
0.026
0.278 W/m2K
Full Fill Fibotherm Insulating Block

OPTION 4
FULL FILL

Outside resistance
105mm brick
100mm Dritherm 32
100mm Stowell Fibotherm
12.5mm drylining on Dabbs
Inside resistance
Sum of resistances
Uncorrected U-value
Correction
U-VALUE
0.040
0.136
3.125
0.400
0.230
0.130
4.061 m2K/W
0.246 W/m2K
0.026
0.272 W/m2K
Partial Fill Fibotherm Insulating Block
All products are available ex works.
Prices on application.
Telephone our sales office for further information and quotations.
 
 
Stowell Fibotherm blocks are ideal for...
INNER OR OUTER LEAF CAVITY WALLS
PARTITION WALLS
 
Stowell Fibotherm blocks comply with
BS EN 771-3 and offer the following advantages...
HIGH INSULATION
LOW SHRINKAGE
LOW SITE BREAKAGE
LOW DENSITY
GOOD FIXABILITY
EXCELLENT PLASTER KEY
OVEN DRY DENSITY approx 850kg/m3
SIZE mm
approx
weight kg
number per
tonne
440x215x75
6.7
150
440x215x100
9.0
110
440x215x140
12.5
80
440x215x190
17.2
58
MINIMUM COMPRESSIVE
STRENGTH: 3.6N/mm3
THERMAL CONDUCTIVITY:
0.25W/mk* at 3% m/c (inside skin)
0.28W/mk* at 5% m/c (outside skin)
THERMAL RESISTANCE
Size mm
m2K/W at:
 
440x215x75
3%m/c 0.8
5%m/c 0.27
440x215x100
3%m/c 0.10
5%m/c 0.36
440x215x140
3%m/c 0.14
5%m/c 0.50
440x215x190
3%m/c 0.19
5%m/c 0.68
(m/c = moisture content)
DRYING SHRINKAGE: 0.026% - 0.04%
FIRE RESISTANCE :
Fibotherm blocks are manufactured using Class 1 lightweight aggregates which are processed at approx. 1150°C (melting point in excess of 1250°C).
* Tested by BRE
** For walls, U-value calculations of 0.35 W/m2K or lower must be obtained for new dwellings (L1A) but in practice, to achieve satisfactory SAP rating, walls need to be designed in the region of 0.28 W/m2K to 0.30 W/m2K. 0.30 W/m2K is the requirement for work on existing buildings (L1B).